  • Microporous Titanium Alloy Stem(JX M1102A) (JX T1102D)

    Microporous Titanium Alloy Stem(JX M1102A) (JX T1102D)

    1. The product is designed with a 12/14 standard taper. 2. The highly polished shoulder and neck design minimizes wear particles produced from the prosthesis impingement during joint motion. 3. The neck is geometrically designed to increase the range of motion of the joint. 4. The vacuum plasma titanium spraying technique is used for the proximal surface, the appropriate thickness and porosity of which are favorable for bone ingrowth and provide the optimal long-term fixation strength. 5. The...
  • RCH Cemented Femoral Stem(JX 1401H) (JX 1402G) (JX 1403H)

    RCH Cemented Femoral Stem(JX 1401H) (JX 1402G) (JX 1403H)

    1. Standard and elongated femoral stems are available, and they are suitable for primary and revision surgeries. 2. The neck is geometrically designed to increase the range of motion of the joint. 3. Collarless, three-dimensional tapered design, increasing tightness during natural subsidence, thus creating autogenous locking. 4. The highly polished surface minimizes the wear between the prosthesis and the bone cement sheath. 5. The distal centralizer is provided with a receptacle design, whic...
  • Microporous Titanium Alloy Stem (HA Coated) (Coarse Titanium Coated) (JX T1103E JX T1103D)

    Microporous Titanium Alloy Stem (HA Coated) (Coarse Titanium Coated) (JX T1103E JX T1103D)

    1. The product is designed with a 12/14 standard taper and a narrowed neck to increase the range of motion of the joint. 2. The proximal trapezoidal cross section provides axial and rotational stability. 3. Three types of femoral stems with HA coating, rough titanium coating and double spray coating are available. 4. The product is designed with a lateral slopping shoulder and is easy to implant to reduce the risk of intraoperative greater trochanter fracture. 5. The proximal stepped design, ...
  • Microporous Titanium Alloy Stem (DAA Stem) (JX F1104D)

    Microporous Titanium Alloy Stem (DAA Stem) (JX F1104D)

    1. The product is designed with a narrowed neck to increase the range of motion of the joint. 2. The reduced lateral shoulder protects the greater trochanter and allows minimally invasive surgeries. 3. The rough titanium coating assures an excellent bone ingrowth effect. 4. The distal grooves provide channels for blood and debris during implantation. 5. An arc-shaped distal end is provided to avoid distal lateral bone impingement. Application Based on an original metaphyseal fixation ...
  • RWH CONE Cementless Femoral Stem (JX F1105A)

    RWH CONE Cementless Femoral Stem (JX F1105A)

    1. Eight longitudinal ridges on the stem body effectively anchor the bone cortex and increase the surface area of the stem body, which is conducive to the prosthesis stability and provides optimal rotational stability and axial stability. 2. The conical stem body is convenient for anteversion angle adjustment. 3. The stem body has a 5-degree taper, which is conducive to the implantation of the prosthesis in a very fine pulp cavity and can effectively prevent subsidence. 4. The tapered geometr...
  • RWH Integrated Cementless Femoral Stem (JX F1103A)

    RWH Integrated Cementless Femoral Stem (JX F1103A)

    1. It is an integrated tapered stem made of Angle Diameter Specification forging titanium alloy. 2. The 2-degree taper of the stem body effectively prevents subsidence and allows the anteversion angle adjustment. 3. Eight longitudinal ridges are designed to improve the initial stability and anti-rotational effect. 4. The length varies between 190 mm and 265 mm. 5. Simple and accurate tools. 6. Similar stem products have shown excellent clinical outcomes for more than 20 years, and the Swedish...
  • Stem for Intertrochanteric Fracture (JX 1201A)

    Stem for Intertrochanteric Fracture (JX 1201A)

    1. The product is designed with a 12/14 standard taper. 2. The thru-hole design of the proximal end of the stem body facilitates the reconstruction of the greater trochanter fracture and maximizes the preservation of the function of the abductor muscle group. 3. Different models of proximal prostheses may be selected based on the calcar defect. 4. The combination with the current bone cement application technique can provide the optimal fixation technique. 5. Co-Cr-Mo alloy material. 6. Optim...
  • Femoral Head (JX 4301) and Semi-hip Bipolar Head (JX 4701)

    Femoral Head (JX 4301) and Semi-hip Bipolar Head (JX 4701)

    Femoral Head (JX 4301) 1. Forging Co-Cr-Mo alloy material. 2. The highly polished surface leads to a low coefficient of friction. 3. With the 12/14 standard taper, a variety of diameters and lengths are available for clinical use. Product Model Specification Head Diameter NH1022S 22S 22 NH1022M 22M 22 NH1022L 22L 22 NH1028S 28S 28 NH1028M 28M 28 NH1028L 28L 28 NH1028XL 28XL 28 NH1032S 32S 32 NH1032M 32M 32 NH1032L 32L 32 NH1032XL 32XL 32 Semi-hip ...