OEM China Partial Tka - Unicompartmental Knee Prosthesis- XU Unicompartmental Knee Arthroplasty – Lidakang
OEM China Partial Tka - Unicompartmental Knee Prosthesis- XU Unicompartmental Knee Arthroplasty – Lidakang Detail:
1.
Anatomically contoured design matches the patient’s bone structure perfectly.
2.
The curves with multiple radiuses at the condyle of femur provides better postoperative feelings for patients
3.
The extended posterior condylar surface results in a better rollback motion and the increased stability in high flexion.
4.
The low-constraint articular surface limits the knee motion to a less extent so that the knee moves more freely.
5.
The three fixation columns below the tibial tray provide a stable placement platform for the prosthesis and simplify the surgical procedure.
6.
More specifications of prostheses are available to satisfy the individual variations among patients.
Main Technical Parameters of Femoral Condylar Unicompartmental DK01
Unit (mm)
Specification and Dimensions |
1# |
2# |
3# |
4# |
5# |
ML |
15 |
17 |
19 |
21 |
23 |
AP |
40 |
43 |
46 |
50 |
55 |
Main Technical Parameters of Tibial Tray Unicompartmental DT01
Unit (mm)
Specification and Dimensions |
S1# |
1# |
2# |
3# |
4# |
5# |
ML |
23 |
25 |
27 |
29 |
31 |
33 |
AP |
40 |
44 |
46 |
49 |
52 |
56 |
Main Technical Parameters of Tibial Insert Unicompartmental DD01
Unit (mm)
Specification and Dimensions |
S1# |
1# |
2# |
3# |
4# |
5# |
ML |
23 |
25 |
27 |
29 |
31 |
33 |
AP |
37 |
40 |
44 |
46 |
49 |
52 |
product presentation
Unicondylar replacement surgery is a partial replacement of only part of the articular surface, preserving most of the articular surface and structures. The unicondylar replacement is an intra-articular surgery, which releases as little of the surrounding soft tissue as possible, especially the medial collateral ligaments, and allows the patient to have better proprioception and more natural movement after surgery. Patient often forget they already took the surgery. The Intraoperative blood loss is minimum, which makes this procedure quite suitable for elderly patients.
Most elderly patients have many underlying diseases, such as hypertension, diabetes, and coronary artery disease, and unicondylar replacement surgery is less invasive and take less time, reducing serious postoperative complications.
Product detail pictures:
Related Product Guide:
We have our own sales team, design team, technical team, QC team and package team. We have strict quality control procedures for each process. Also, all of our workers are experienced in printing field for OEM China Partial Tka - Unicompartmental Knee Prosthesis- XU Unicompartmental Knee Arthroplasty – Lidakang , The product will supply to all over the world, such as: Mozambique, San Francisco, Kenya, We've a skilled sales team, they have mastered the best technology and manufacturing processes, have years of experience in foreign trade sales, with customers able to communicate seamlessly and accurately understand the real needs of customers, providing customers with personalized service and unique merchandise.
By Carey from Ethiopia - 2017.06.29 18:55
In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
By Ivan from Orlando - 2018.12.11 11:26