X4 Knee implants are used to eliminate the patient’s complaints regarding functionally or dimensionally deformed knee joints, besides in patients with decreases life quality caused by pain relating to arthrosis. Knee joint prostheses consist of the following parts; femoral components, inserts, tibial components, stems, pegs, nuts, patellar components.


Product Detail

Product Tags

Related Video

Feedback (2)

Being supported by an state-of-the-art and skilled IT team, we could supply technical support on pre-sales & after-sales service for Ha Coated Implants, Compartmental Knee Replacement, Partial To Total Knee Revision, As an expert specialized in this field, we are committed to solving any problem of high temperature protection for users.
OEM/ODM Factory Partial Total Knee Replacement - TKA Prosthesis- LDK X4 Primary Total Knee Arthroplasty – Lidakang Detail:

1.

The anterior condyle of the femoral prosthesis is provided with reduced width and thickness to decrease the anterior condyloid pressure and quadriceps tension. The same sagittal geometry and the smooth curvature allow the patella not to increase the force of the quadriceps femoris when the knee stretches and flexes. In combination with the deep patellar trochlear groove, it can be ensured that the patella is stable and in the groove even in high flexion without dislocation, and steady contact between the patella and femoral prosthesis is maintained at all times.

2.

The femoral prosthesis is designed with a slightly curved coronal plane to maximize the contact area so as to reduce peak pressure on the polyethylene insert. The point-to-point edge bearing is eliminated during the varus-valgus rotation of the knee, so that the tibiofemoral joint always maintains face-to-face contact.

3.

The anterior patellar notch of the polyethylene insert reduces the additional pressure and tension on the quadriceps femoris during high flexion.

4.

The posterior condylar curvature is increased. The tibiofemoral articular surface remains surface contact rather than point contact when flexion is up to 135 degrees.

5.

Open intercondylar fossa design: The intercondylar osteotomy is reduced, and the bone is preserved to the greatest extent for the patient.

6.

Optimized cam-post structure: The cam is still maintained at the base of the column while the knee is in high flexion, preventing the occurrence of cervical dislocation during high flexion to a limited extent.

7.

A unique insert locking mechanism is provided. The secondary fixation with metal anchors can eliminate the fretting wear between the two.

8.

The tri-wing structure prevents rotation and avoids stress concentration.

Femoral Condyle Specification

Femoral Condyle Specification
Femoral Condyle Specification

Material: Co-Cr-Mo
Main Technical Parameters of Femoral Condyle (RY A201)
Unit (mm)

Product Model Specification Transverse Diameter AP Diameter
50111P 1L 57 53
50112P 2L 60 56
50113P 3L 63 59
50114P 4L 66 62
50115P 5L 71 66
50116P 1R 57 53
50117P 2R 60 56
50118P 3R 63 59
50119P 4R 66 62
50120P 5R 71 66

Tibial Tray Specification

Tibial Tray Specification
Tibial Tray Specification

Material: Co-Cr-Mo
Main Technical Parameters of Tibial Tray (RY B401)
Unit (mm)

Product Model Specification Transverse Diameter AP Diameter
50126 1# 61 41
50127 2# 64 43
50128 3# 67 45
50129 4# 71 47
50130 5# 76 51

Tibial Insert Specification

Tibial Insert Specification
Tibial Insert Specification

aterial: Ultra-High Molecular Weight Polyethylene
Main Technical Parameters of Tibial Insert (RY C401)
Unit (mm)

Product Model Specification Transverse Diameter AP Diameter
50126 1# 61 41
50127 2# 64 43
50128 3# 67 45
50129 4# 71 47
50130 5# 76 51

Patella

Patella
Patella

Material: Ultra-High Molecular Weight Polyethylene
Main Technical Parameters of Patella (RY D01)
Unit (mm)

Product Model Specification Transverse Diameter AP Diameter
50147B-8  Φ30/ 8 Φ30 8
50141B-8  Φ32/ 8 Φ32 8
50141B-10  Φ32/ 10 Φ32 10
50142B-8  Φ35/ 8 Φ35 8
50142B-10  Φ35/ 10 Φ35 10
50143B-10  Φ38/ 10 Φ38 10

Product detail pictures:

OEM/ODM Factory Partial Total Knee Replacement - TKA Prosthesis- LDK X4 Primary Total Knee Arthroplasty – Lidakang detail pictures

OEM/ODM Factory Partial Total Knee Replacement - TKA Prosthesis- LDK X4 Primary Total Knee Arthroplasty – Lidakang detail pictures


Related Product Guide:

Sticking for the principle of Super Quality, Satisfactory service ,We have been striving for being a superb small business partner of you for OEM/ODM Factory Partial Total Knee Replacement - TKA Prosthesis- LDK X4 Primary Total Knee Arthroplasty – Lidakang , The product will supply to all over the world, such as: Niger, kazan, Stuttgart, The company has numbers of foreign trade platforms, which are Alibaba,Globalsources,Global Market,Made-in-china. XinGuangYang HID brand products sell very well in Europe, America, Middle East and other regions more than 30 countries.
In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
5 Stars By Sharon from Canada - 2017.02.28 14:19
This company has the idea of better quality, lower processing costs, prices are more reasonable, so they have competitive product quality and price, that's the main reason we chose to cooperate.
5 Stars By Tom from Durban - 2018.12.22 12:52
Write your message here and send it to us